Winow 10kg CO₂ Wheeled Fire Extinguisher
The Winow 10kg CO₂ Wheeled Fire Extinguisher provides high-capacity, clean and residue-free protection for electrical equipment and flammable-liquid fire risks. It features a mobile wheeled design, flexible high-pressure hose, directional discharge horn, operating valve and safety mechanism. Ideal for server rooms, electrical panels, factories, workshops, laboratories, generator rooms and other commercial or industrial premises.
The Winow 10kg CO₂ Wheeled Fire Extinguisher is a high-capacity fire protection unit designed for environments containing electrical equipment, machinery and flammable-liquid fire risks. Filled with 10kg of carbon dioxide extinguishing agent, it delivers a clean and residue-free discharge that helps control fire without covering equipment in powder, foam or water.
Its larger capacity makes it suitable for commercial and industrial premises requiring more extinguishing power than a standard handheld CO₂ extinguisher. The unit is fitted with a flexible high-pressure discharge hose and a large directional horn, allowing the operator to apply the carbon dioxide toward the affected area while maintaining a practical distance.
The extinguisher also features a mobile wheeled design to assist with movement and positioning. This makes it particularly useful in larger facilities such as electrical rooms, workshops, factories, laboratories and production areas.
Suitable Fire Risks
The Winow 10kg CO₂ Fire Extinguisher is primarily suitable for:
- Fires involving energised electrical equipment
- Electrical control panels and switchgear
- Computers, servers and communication equipment
- UPS systems and power-control equipment
- Class B fires involving compatible flammable liquids
- Machinery and equipment where a residue-free extinguishing agent is preferred
Always confirm the applicable fire classifications from the product label and local fire safety requirements.
Key Product Features
- 10kg carbon dioxide extinguishing-agent capacity
- Clean and residue-free fire suppression
- Suitable for electrical-equipment and flammable-liquid fire risks
- Large-capacity design for commercial and industrial protection
- Flexible high-pressure discharge hose
- Large directional CO₂ discharge horn
- Insulated horn grip for safer handling
- Strong operating valve and control lever
- Safety pin and tamper seal to reduce accidental discharge
- Durable high-pressure steel cylinder
- Mobile wheeled design for easier positioning
- Highly visible red cylinder with black CO₂ identification
- Suitable for locations containing valuable or sensitive equipment
- Does not release powder, water or foam onto protected equipment
Product Specifications
- Brand: Winow
- Product Type: Wheeled carbon dioxide fire extinguisher
- Extinguishing Agent: Carbon dioxide gas
- Agent Capacity: 10kg
- Primary Applications: Electrical equipment and flammable-liquid fire risks
- Discharge System: Flexible high-pressure hose with directional horn
- Operation Type: Manual control valve
- Safety Mechanism: Safety pin with tamper seal
- Mobility: Integrated wheel assembly
- Cylinder Construction: High-pressure steel cylinder
- Cylinder Colour: Red
- Identification Colour: Black
- Placement Type: Floor-standing mobile extinguisher
- Recommended Servicing: By a qualified fire safety technician
Recommended Applications
The Winow 10kg CO₂ Wheeled Fire Extinguisher is suitable for:
- Server rooms and data centres
- Electrical control rooms
- Switchgear and electrical-panel areas
- Factories and manufacturing facilities
- Workshops and engineering facilities
- Generator and machinery rooms
- Telecommunications facilities
- Computer laboratories
- Hospitals and healthcare facilities
- Hotels, lodges and commercial buildings
- Printing and production areas
- Warehouses containing suitable fire risks
- Airports and transport facilities
- Industrial plants
- Laboratories
- Power and utility facilities
Benefits of Carbon Dioxide Fire Suppression
Carbon dioxide is especially useful in environments containing electrical and electronic equipment because it does not leave a powder or liquid residue after discharge. This can help reduce secondary contamination and minimise the cleaning required around valuable equipment.
The discharged gas works by reducing the oxygen available around the fire. Because it leaves no residue, it is commonly selected for server rooms, control panels, laboratories, communication equipment and machinery areas.
Benefits of the 10kg Capacity
The 10kg model provides a larger quantity of extinguishing agent than smaller portable CO₂ extinguishers. This makes it more suitable for larger risk areas or facilities containing several pieces of electrical or industrial equipment.
Its mobile design helps trained personnel move the unit toward the affected area while the long hose and directional horn provide improved reach and controlled application.
Important Safety Information
Carbon dioxide fire extinguishers require careful handling. During discharge, the horn and nearby components can become extremely cold. The horn should only be held using its insulated grip.
Carbon dioxide can also reduce oxygen levels, particularly in small, enclosed or poorly ventilated spaces. Users should not remain in an area where a large quantity of CO₂ has been discharged. The area should be evacuated and properly ventilated before re-entry.
This extinguisher should not normally be used as the primary extinguisher for:
- Deep-seated fires involving wood, paper, textiles or furniture
- Cooking-oil and deep-fat fryer fires
- Combustible-metal fires
- Flammable-gas leaks where the gas supply has not been isolated
- Fires inside small confined spaces without a safe evacuation route
- Any fire that has grown beyond the safe capability of portable firefighting equipment
Carbon dioxide provides limited cooling, so some materials may reignite after the gas disperses.
Placement and Accessibility
The extinguisher should be positioned in a clearly visible, properly marked and easily accessible location near the identified fire risk. Suitable placement areas may include entrances to server rooms, electrical rooms, laboratories, workshops and machinery areas.
The floor around the extinguisher should remain clear so the unit can be moved without obstruction. The hose, horn, operating valve and wheels must remain accessible at all times.
Inspection and Maintenance
The extinguisher should be inspected regularly to confirm that it remains ready for emergency use. Routine checks should include:
- Confirming that the safety pin and tamper seal are intact
- Inspecting the cylinder for dents, corrosion or physical damage
- Checking the hose for cracks, cuts or deterioration
- Ensuring the discharge horn is secure and unobstructed
- Inspecting the operating valve and lever
- Checking that the wheels move correctly
- Confirming that the extinguisher remains visible and accessible
- Checking the unit’s weight according to the servicing schedule
- Looking for evidence of leakage, previous discharge or tampering
- Confirming that operating instructions remain readable
Professional weighing, inspection and servicing should be completed according to the manufacturer’s recommendations and applicable fire safety requirements. After any discharge, including partial use, the extinguisher must be professionally inspected and refilled before being returned to service.